The 1745-E101 is a Bulletin 1745 SLC 100 basic expansion unit with 10 AC inputs and 6 hard-contact outputs.
Nhãn hiệu :
PLCmột phần số :
1745-E101Trọng lượng :
Verify from official installation drawingKích thước :
Verify from official installation drawingnước xuất xứ :
85–132/170–265 V AC, 50/60 HzMã HS :
SLC 100 Basic Expansion UnitSự mô tả :
The 1745-E101 is a Bulletin 1745 SLC 100 basic expansion unit with 10 AC inputs and 6 hard-contact outputs.Click “+” to expand more specifications.
Source: Official publication 1745-UM001 and the exact official product cutsheet support 1745-E101 technical specifications. Verify the full catalog number, 85–132 V AC class, 6 hard-contact output, duty ratings, frame, enclosure, input, filtering, braking and Exact unit type configuration before replacement.
1745-E101 is a SLC 100 Basic Expansion Unit documented in official publication 1745-UM001.
1745-E101 provides 16 I/O: 10 inputs and 6 outputs; verify each field circuit against the official wiring diagrams.
1745-E101 uses 10 current-sinking inputs · 85–132 V AC, 50/60 Hz according to official publication 1745-UM001.
1745-E101 uses 6 hard-contact outputs · 10–250 V AC / 10–125 V DC; confirm the connected load voltage and output type before wiring.
1745-E101 uses 85–132/170–265 V AC, 50/60 Hz incoming power; verify the line terminals and fuse arrangement.
1745-E101 is specified with Not applicable; expansion I/O unit and Controlled by the connected SLC 100 processor.
1745-E101 requires verification of the complete catalog number, incoming power, I/O voltage, output type, terminal wiring and connected Bulletin 1745 system.
Official manufacturer-reference information for the 1745-E101 SLC 100 Basic Expansion Unit.
Official publication 1745-UM001 identifies 1745-E101 and its documented electrical and I/O data.
OFFICIAL MANUALSend the complete model, quantity, nameplate photos and your technical or purchasing question.
Technical statements on this page are limited to official manufacturer publication 1745-UM001 for 1745-E101. No third-party product sources were used.
1745 identifies the SLC 100 family; in E identifies the expansion unit designation; 101 identifies the slc 100 basic expansion variant with 85–132 v ac inputs; .
Bulletin 1745 controller family.
Expansion unit designation.
SLC 100 basic expansion variant with 85–132 V AC inputs.
E identifies an expansion unit; 101 identifies the SLC 100 basic expansion version with 85–132 V AC input circuits.
Match 1745-E101 to the complete unit label and installed Bulletin 1745 documentation.
Confirm 10 AC inputs, 6 hard-contact outputs, 12 VA maximum power and the 85–132 V AC input-circuit range.
Confirm the incoming power, input circuit range, output wiring and connected controller or expansion arrangement.
Confirm the complete catalog number, terminal wiring, fuse protection and environmental limits before replacement.
A clear workflow for sourcing, verification, shipment preparation, delivery and product assurance.
Include the complete part number, quantity and delivery destination.