GE CPCA · CONTACTOR PILOT CARD

DS200CPCAG1A

DS200CPCAG1A is a GE contactor pilot card. The manufacturer's DS200CPCAG1A drawing and CPCA description identify a 115 V ac input rectified to 105 V dc for a nominal 115 V dc contactor coil. CPCA applies full voltage during closing and holding and has no adjustable hardware.

PRODUCT TYPECONTACTOR PILOT CARD
PLATFORMDC2000 / EX2000
POWER INPUT115 V ac
COIL DRIVE105 V dc
MANUFACTURERGE
CONDITION / WARRANTYOriginal New · One-Year Warranty
ISO CERTIFICATIONISO-Certified Product
VERIFICATION● Product photos and videos provided after inquiry
REQUEST A QUOTE
  • một phần số :

    DS200CPCAG1A
  • Sự mô tả :

    Contactor Pilot Card
MODEL SEARCHFind a specific part numberOpen the best-matched Moore Automation product page directly.
GE ● CONTACTOR PILOT CARD
DC2000 / EX2000

DS200CPCAG1A

CONTACTOR PILOT CARD

GE DC2000 / EX2000 · CPCA CONTACTOR PILOT

MODULE ROLE
DS200CPCAG1A is the G1A CPCA contactor pilot card shown in GEH-6005. Its function is to provide rectified power for contactor closing and holding.
LONG DESCRIPTION
DS200CPCAG1A uses 115 V ac input to produce the documented 105 V dc coil-driving supply for a nominal 115 V dc contactor coil. The CPCA applies full voltage during closing and holding and contains no adjustable hardware. The terminal board provides a series interlock path and a power connection parallel with RMPL; the drawing identifies separate power and coil-control testpoints.
👩‍💼
WANT THE BEST PRICE?
Frida
Sales Leader 🏆
EMAILsales5@mooreplc.com WHATSAPP+86 153 5940 8275
ORDER NUMBER BREAKDOWN

How the DS200CPCAG1A Reference Is Structured

DS
Manufacturer identifierGE Drive Systems & Turbine Controls
200
Assembly levelBase-level board assembly
CPCA
Functional acronymContactor Pilot Card
G1
Board groupGroup 1
A
Revision identifierRevision A
MANUFACTURER-REFERENCE CHARACTERISTICS

Technical Specifications

DC2000 / EX2000 ↗
DS200CPCAG1A CONTACTOR PILOT CARD

Engineering data at a glance

Click “+” to expand more specifications.

AC INPUT115Vac
DC DRIVE105Vdc
COIL CLASS115Vdc
ADJUSTMENTFixed
CPCA electrical relationship: 115 V ac input, 105 V dc rectified coil drive and a nominal 115 V dc contactor-coil class. Hardware adjustment is fixed.
Continuous coil-voltage method The CPCA card DS200CPCAG1A uses full rectified voltage to close and hold the contactor. The 105 V dc drive value and nominal 115 V dc coil class describe different parts of that electrical relationship.
GENERAL INFORMATION −
BrandGE
Part numberDS200CPCAG1A
Product typeContactor Pilot Card
Input power115 V ac
Rectified coil-drive voltage105 V dc
Nominal contactor-coil class115 V dc
CONTROL & POWER INTERFACE +
Series interlock connection1TB-1 and 1TB-2 in the MACPL coil-driving path
Power terminals1TB-11: hot/+; 1TB-12: neutral/−
Parallel power connection1TB-11/12 are parallel with RMPL pins 1/2
BOARD TESTPOINTS & ADJUSTMENTS +
Power-input testpointsCPH and CPN
Coil-control testpointsPSP and PSN
Adjustable hardwareNone; no CDBA-style RV1 holding-current adjustment
CONTACTOR DRIVE METHOD +
Full-voltage operation: CPCA rectifies the incoming ac supply and applies the resulting full dc voltage to close and hold the contactor. It does not use CDBA's timed forced-pickup and regulated-current holding sequence.
Source: GEH-6005, figure 5-5 and CPCA sections 5-4.3, 6-6 and 7-6.2; GEH-6120B, pages 5-3–5-4, CPCA function and terminal/connector tables. No manufacturer-hosted instruction PDF was confirmed.
FAQ

Questions Buyers Ask Most

What supply conversion is documented for DS200CPCAG1A?+

For DS200CPCAG1A, GE identifies 115 V ac input rectified to 105 V dc for the contactor coil. The contactors used with CPCA have a nominal 115 V dc coil rating.

Does DS200CPCAG1A use a short pickup pulse followed by current regulation?+

No. DS200CPCAG1A applies full rectified voltage for both closing and holding. The separate CDBA board type uses the timed pickup and regulated holding-current method.

Does DS200CPCAG1A include adjustable holding-current hardware?+

No. The manufacturer states that CPCA has no adjustable hardware. A CDBA-style RV1 adjustment should not be assigned to DS200CPCAG1A.

Where is the series coil interlock connected on DS200CPCAG1A?+

On DS200CPCAG1A, 1TB-1 and 1TB-2 provide the series interlock connection in the coil-driving path from MACPL.

How are the power terminals related to RMPL on DS200CPCAG1A?+

On DS200CPCAG1A, 1TB-11 is the hot/+ power input and 1TB-12 is neutral/−. They are electrically parallel with RMPL pins 1 and 2, respectively.

Which testpoints distinguish the power and control inputs on DS200CPCAG1A?+

For DS200CPCAG1A, CPH/CPN identify power-input testpoints and PSP/PSN identify coil-control input testpoints in the manufacturer's CPCA diagram and testpoint table.

CONTACT PRODUCT SPECIALIST

Check your configuration with Frida

Share the complete order number and application details for compatibility, availability and lead-time checking.

CHOOSE A DIRECT CONTACT METHOD
DATA SHEET

Product Information for
DS200CPCAG1A

Official manufacturer-manual PDF status for GE DS200CPCAG1A.

Official manual PDF status

A direct manufacturer-hosted instruction-manual PDF covering DS200CPCAG1A was not located in the public documentation checked. For the applicable manual and product documentation, please contact Product Specialist Frida.

CONTACT FRIDA

Contact to Get Support

Send the complete model, quantity, and your technical or purchasing question.

GEH-6005, figure 5-5 and CPCA sections 5-4.3, 6-6 and 7-6.2; GEH-6120B, pages 5-3–5-4, CPCA function and terminal/connector tables. No manufacturer-hosted instruction PDF was confirmed.

GE CONTACTOR PILOT RELATIONSHIP

How DS200CPCAG1A Fits Contactor Pilot Control

GE is the manufacturer brand; GE DC2000 Drives / EX2000 Excitation is the product family; and DS200CPCAG1A is the contactor pilot card for DC2000 and EX2000 contactor-coil control.

GE · BRAND
GE DC2000 Drives / EX2000 ExcitationContactor Pilot Card
SYSTEM ROLE

Contactor Pilot Card

Supplies full rectified voltage for contactor closing and holding through the configured coil-control and interlock circuit.

MODULE / CONFIGURATION

115 V ac input · 105 V dc drive

The documented CPCA circuit uses a nominal 115 V dc contactor coil and has no adjustable hardware.

COIL CONTROL & POWER INTERFACE

DS200CPCAG1A · Contactor Pilot Card

MACPL participates in the coil-control path; 1TB-1/2 provide a series interlock, and 1TB-11/12 parallel the RMPL power pins.

System relationship: the control path and series interlock govern the CPCA, which rectifies the ac supply and applies dc power to the contactor coil.
APPLICATION AREAS

Application map for DS200CPCAG1A

Contactor ClosingProvide the documented full-voltage coil drive
Contactor HoldingMaintain rectified coil voltage after closing
CONTACTOR PILOT POWER & CONTROL DS200CPCAG1A DS200CPCAG1A · Contactor Pilot Card
Series InterlockIntegrate the coil-driving interlock path
Drive / Exciter InterfaceUse CPCA in the manufacturer-described DC2000 or EX2000 control arrangement
ABOUT MOORE AUTOMATION

A trusted industrial automation sourcing partner

Moore Automation Limited supplies industrial automation spare parts to customers worldwide, with dedicated sourcing, part-number verification, pre-shipment confirmation and responsive sales support.

Global sourcing Pre-shipment verification One-year warranty
SERVICE

Industrial Automation Order Support

A clear workflow for sourcing, verification, shipment preparation, delivery and product assurance.

STAGESERVICE ACTIONWHAT WE CHECK OR PROVIDE
01PROCUREMENT
Product SourcingCurrent, hard-to-find and discontinued industrial automation parts.
02VERIFICATION
Part Number ReviewComplete model, suffix, nameplate, visible revision and application details.
03CONFIRMATION
Pre-Shipment CheckModel, label, condition and packaging confirmed with actual photos or video.
04FULFILLMENT
Global Delivery
Worldwide delivery with flexible shipping options. We support door-to-door pickup or delivery to your nominated freight forwarder in China.
DHLFedExUPSTNT
05ASSURANCE
One-Year WarrantyOne-year warranty from delivery for products supplied by Moore Automation.
Warranty Claim Information+
What to provide: If a product-related issue occurs within the warranty period, contact our team and submit one clear, continuous video for review.
✓Complete product and nameplate
✓Power supply and wiring connections
✓Installation and operating conditions
✓Indicator lights, alarms or error messages
✓Clear description of the fault
✓Continuous video showing the issue
Review outcome: If the evidence confirms a covered product fault, Moore Automation will arrange the appropriate warranty solution.
SALES ASSISTANCE

Contact Sales Manager Frida

Include the complete part number, quantity and delivery destination.

EMAILsales5@mooreplc.com WHATSAPP+86 153 5940 8275
Same-brand recommendations

GE Related Models

GE ↗PACSystems and Field Control models
Customers Also Source from Moore

Hot-selling Models

Select a brand to view models
OTHER BRANDSSelected measurement and automation models
Fisher67CFRInstrument Supply Regulator
Rosemount3051CD4A22A1AM5B4DFE5Pressure Transmitter
Rosemount3051CG3APressure Transmitter
Rosemount3051CG4A22APressure Transmitter
Endress+HauserCLD18Conductivity Measurement System
Endress+HauserCLS15-A1A1AConductivity Sensor
Endress+HauserCLS50D-AA2C21Conductivity Sensor
Endress+HauserCLS54Conductivity Sensor
Endress+HauserCOS61D-1020/0Dissolved Oxygen Sensor
Endress+HauserCPM253-CP00015pH/ORP Transmitter
AccuenergyIIR-M-RCT-P1Power and Energy Meter
OmronCJ1W-DA021Analog Output Unit
để lại lời nhắn
Nếu bạn quan tâm đến sản phẩm của chúng tôi và muốn biết thêm chi tiết, vui lòng để lại tin nhắn ở đây, chúng tôi sẽ trả lời bạn ngay khi có thể.
Gửi đi
  • plc
  • DCS
  • TSI
  • HMIS
Sản phẩm liên quan